Panasonic 5.0kW Standard Developer RZ Series Split System Air Conditioner

$1,285.00

Panasonic wall mounted split system air conditioner.

Installation

Product price
Additional options total:
Order total:
We ship Australia wide. Shipping time approximately 2 to 3 weeks. See terms and conditions for details. Please call 1300 797 468 to confirm lead time.
Panasonic

Panasonic 5.0kW Standard Developer RZ Series wall mounted split system is packed with features.

The 5.0kW CS-RZ50VKR / CU-RZ50VKR Features:

Energy Saving Features:

  • Inverter Control –  Varies the rotation speed of the compressor for higher energy savings
  • Eco Mode – More energy saving compared to the normal mode by automatically adjusting the set temperature by up to 2ºC. It’s ideal when you want to maintain room temperature for gentle cooling and heating

Comfort Features:

  • Quiet Mode – Enjoy the comfort of running your air conditioner at night and still have a relaxing sleep.
  • Personal Airflow Creation – Vertical and horizontal airflow patterns can be combined as desired to achieve optimum comfort, with operation possible by remote, even from a distance.
  • Fan Mode – Allows you to run the fan without any cooling or heating, thus giving just ventilation.
  • Auto Changeover (inverter) – In Auto Mode the unit will select if heating or cooling is required.
  • Powerful Mode – Pressing the Powerful button cools or heats the room quickly. It provides fast comfort, with full power and a strong airflow. This is perfect for use immediately after coming home, or when unexpected guests arrive.
  • Soft Dry Operation Mode – Starts with cooling to dehumidify, then provides continuous breeze at a low frequency to keep a room dry without much change to the temperature.
  • Hot Start Control – On the start of the heating cycle and after the defrost cycle, the indoor fan will start up once the indoor heat exchanger is warm.

Clean and Healthy Air Features:

  • Anti-Bacterial Filter – The anti-bacterial filter combines three effects in one: anti-allergen, anti-virus and antibacterial to provide clean air.
  • Odour Removing Function – With this function, there’s no unpleasant odour when the unit starts up. That’s because the fan remains off momentarily, while the source of the odour inside the air conditioner is suppressed. The unit must be in cool or dry mode and the fan speed must be set to automatic.
  • Removable Washable Panel – Gives you easy access to the filter as well making the unit easy to clean.

Convenience Features:

  • 24-Hour Dual on and Off Real Setting Timer – This feature enables you to preset two different sets of start/stop operation timer (hour and minute) within a 24-hour time frame.
  • 3rd Party Connectivity – Allows limited control from an external source when wired to do so.
  • Wired Remote Control (Optional) – For use in commercial applications, or where users don’t want a remote control.
  • Demand Response Enabling (DRED) – Allows Electrical Utility Companies to regulate the power supply to the units if connected.
  • LCD Wireless Remote Control – Easy control of the unit from anywhere in the room.
  • Wireless LAN Remote Control for Internet Connection (Optional) – Control air conditioners remotely by turning your mobile desire into a remote controller using internet connection. Adaptor CZ-TACG1 Sold Separately

Reliability Features:

  • Blue Fin Condenser – Extra protection from the elements with a longer lasting coil.
  • Long Piping – Long piping offers more flexible installation options. *20m – CS-Z20VKR, CS-Z25VKR, CS-Z35VKR *30m – CS-Z42VKR, CS-Z50VKR, CS-Z60VKR, CS-Z71VKR, CS-Z80VKR
  • Self-Diagnostic Function – Should a malfunction occur, the unit diagnoses the problem and shows the corresponding alphanumeric code. This allows for quicker servicing.
  • Random Auto Restart – When multiple units are connected and there is a power outage, they will turn on at different times in order to not spike the power supply.
  • Top Panel Maintenance Access – Easy access for maintenance.

More information on Panasonic RZ series air conditioners is available at their website here.

If you need installation information head over to our installation page here.

Size (kw)

Colour

Wifi

Yes, add on required

Specifications

SpecificationUnitDetails
Indoor Model Number-CS-RZ50VKRW
Outdoor Model Number-CU-RZ50VKR
Power SupplyV/Ph/Hz240/1/50
Cooling Capacity (min-max)kW5.0 (0.98-5.60)
Heating Capacity (min-max)kW5.80 (0.98-7.80)
Cooling Capacity (min-max)Btu/h17,100 (3340-19,100)
Heating Capacity (min-max)Btu/h19,800 (3340-26,600)
Indoor Air Flow in CoolingL/s332
Indoor Air Flow in HeatingL/s339
DehumidL/h2.80
Running Current in CoolingA6.70
Running Current in HeatingA6.80
Power Input in Cooling (min-max)kW1.47 (0.28-1.73)
Power Input in HeatingkW1.54 (0.26-2.30)
AEER/EERW/W3.37/3.40
ACOP/COPW/W3.74/3.77
Energy Rating in CoolingStars2.0
Energy Rating in HeatingStars2.5
Indoor Sound Pressure Level in Cooling (H/L/Q-Lo)dB(A)44/34/31
Indoor Sound Pressure Level in Heating (H/L/Q-Lo)dB(A)44/33/29
Outdoor Sound Pressure Level in Cooling (H/Q-Lo)dB(A)48/43
Outdoor Sound Pressure Level in Heating (H/Q-Lo)dB(A)49/44
Indoor Sound Power Level in Cooling (H/L/Q-Lo)dB60/50/47
Indoor Sound Power Level in Heating (H/L/Q-Lo)dB60/49/45
Outdoor Sound Power Level in Cooling (H/Q-Lo)dB63/58
Outdoor Sound Power Level in Heating (H/Q-Lo)dB64/59
Indoor Net Weightkg12
Outdoor Net Weightkg34
Indoor Dimensions (H x W x D)mm302 x 1102 x 244
Outdoor Dimensions (H x W x D)mm619 x 824 x 299
Liquid Pipe Sizemm(inch)ø 6.35 (1/4)
Gas Pipe Sizemm(inch)ø 12.70 (1/2)
Pipe Extension Length (Min-Max)m3-30
Maximum Elevation Lengthm15
Pipe Length for Additional Gasm10
Additional Gas Amountg/m15
Power Supply-Outdoor
Operating Range in Cooling°C-10 - + 46
Operating Range in Heating°C-15 - +24
Refrigerant Type-R32

Quote Request Form

  • Please indicate the best time for us to get in touch to discuss the progress of your quotation. Please note our business hours are 7.30am - 4.00pm.
    Please indicate what type of system you would like a quote on.
  • In cases of one area heating and cooling please indicate room size. In cases of ducted/ central air conditioning please indicate total living floor area.
  • This field is for validation purposes and should be left unchanged.

Scroll to Top